Table 16 PV hazards

From: Comparative economic viability and environmental impact of PV, diesel and grid systems for large underground water pumping application (55 wells) in Jordan

 

Description

Hazard no. 1

Electric shock may cause personnel injury to installers, occupants or others (would include local Disi animals and birds)

 Risk level

Negligible risk region

 Risk reduction

Installation of a well-engineered system and understanding of potential hazard by design team, installation crew and system user. And installation of complete set warning signs where applicable inside and around the PV system

Hazard no. 2

Initiation of contact fire due to increased temperature of Disi area or the possibility of ray reflection from flat surfaces on flammable objects

 Risk level

Tolerable risk region

 Risk reduction

Insulate structure with fire proofing materials and implement a fire safety procedure, along with continuous check for flammable objects that might be available

Hazard no. 3

Theft of PV equipment

 Risk level

Tolerable risk region

 Risk reduction

Hour-round surveillance on the PV plant through either physical present of personnel or computerized systems

Hazard no. 4

Communication Interference (e.g. inverters)

 Risk level

Tolerable risk region

 Risk reduction

Appropriate design and system installation based on good engineering practice must be adopted