Skip to main content

Table 8 Results for 69 bus system with DG at 0.9 pf

From: Optimal DG placement for benefit maximization in distribution networks by using Dragonfly algorithm

 

With DG

Voltage sensitivity index method (Murthy and Kumar 2013)

Proposed method

DG location

65

61

DG size (kVA)

1750

2217.3

TLP (kW)

65.4502

27.9636

TLR (kVAR)

35.625

16.4979

Vmin (p.u.)

0.969302

0.9728

Cost of Energy losses ($)

5268.4297

2249.2

Cost of PDG ($/MW h)

31.75

40.1

Cost of QDG ($/MVAR h)

3.083

4.48