Skip to main content

Table 3 Range of specific speed for each turbine type (Penche, 2004)

From: Design models for small run-of-river hydropower plants: a review

Turbine type

Range speed

Pelton one nozzle

0.005 ≤ nQE  ≤ 0.025

Pelton n nozzles

0.005n0.5 ≤ nQE  ≤ 0.025n0.5

Francis

0.05 ≤ nQE  ≤ 0.33

Kaplan Propeller bulbs

0.19 ≤ nQE  ≤ 1.55